top of page

Application: Airport surface water run off

Solution: Ultraflux Ultrasonic Flowmeter

Application

  • A large airport had to measure surface runoff water flows.

  • Flows went from 10 to 100% full pipe. No power on-site.

  • Flow readings needed to be measured and recorded continuously.

  • Solar power system had to have 14 days autonomy.

Application Details

  • Pipe Size:  1800mm

  • Pipe Material: Concrete

  • Flowrate:   Part full pipe, 40 to 5000 m3/hr

Surface water run off flow meter

Application

Solution

  • The Ultraflux UF800 Ultrasonic flowmeter was specified and installed with a solar power system.

  • The system was web-enabled to allow remote reporting.

  • The system has required zero maintenance since installation in 2008.

Equipment Specified 

  • Ultraflux UF800 Series 2 path open channel flow meter with pressure level sensor.

  • Sensors installed using St.St. mounting bands. No drilling

  • DC powered control unit with a built-in data logger to record flows

  • Web-enabled data logger

  • 120W solar power system with 14-day reserve power

Ultraflux UF821 Flowmeter

Solution

Applications

  • Sewer flows

  • Leakage and infiltration 

  • Industrial effluent

Key Words

  • Part full to fully filled pipe

  • Solar Power 

  • Airport Surface water 

  • Retrofit

  • No maintenance

Solar power system

Installation

airport runoff
bottom of page