Application: Airport surface water run off
Solution: Ultraflux Ultrasonic Flowmeter
Application
-
A large airport had to measure surface runoff water flows.
-
Flows went from 10 to 100% full pipe. No power on-site.
-
Flow readings needed to be measured and recorded continuously.
-
Solar power system had to have 14 days autonomy.
Application Details
-
Pipe Size: 1800mm
-
Pipe Material: Concrete
-
Flowrate: Part full pipe, 40 to 5000 m3/hr

Application
Solution
-
The Ultraflux UF800 Ultrasonic flowmeter was specified and installed with a solar power system.
-
The system was web-enabled to allow remote reporting.
-
The system has required zero maintenance since installation in 2008.
Equipment Specified
-
Ultraflux UF800 Series 2 path open channel flow meter with pressure level sensor.
-
Sensors installed using St.St. mounting bands. No drilling
-
DC powered control unit with a built-in data logger to record flows
-
Web-enabled data logger
-
120W solar power system with 14-day reserve power

Solution
-
Sewer flows
-
Leakage and infiltration
-
Industrial effluent
Key Words
-
Part full to fully filled pipe
-
Solar Power
-
Airport Surface water
-
Retrofit
-
No maintenance

Installation