top of page

Application: Ship Fuel oil
Solution: Ultraflux River Flowmeter

Application

  • Fuel into a ship's engine had to be checked for the correct flow rate

  • Nothing could be inside the pipes

  • The pipe could not be drilled or cut

  • The system had to be robust

Application Details

  • Pipe size:  65mm

  • Pipe material: Steel

  • Flowrate:   4000 kg/hr

  • Temperature: 137 Deg C

Ship fuel oil flow meter

Application

Solution

Equipment Specified 

Ultraflux MINISONIC 600

Solution

Applications

  • Pumped sewer flows

  • Effluent flows

  • Drinking water distribution

  • Process flow

Key Words

  • Fuel oil

  • Retrofit

  • No pipe drilling

PDF images.jpg
Ship engine fuel feed

Installation

Registration: 14654952  VAT: EE102169865

​

       +372 5645 1435 ENG                    

+372 5688 3009 ENG/EST/RUS    

 sales@flowline.ee

Copyright Flowline OÜ 2020

bottom of page