top of page
Application: River Flow
Solution: Ultraflux River Flowmeter
Application
-
The river is located in an SSSI (Protected area)
-
Flow velocities were low
-
Flows from sewage works also discharge in the river
Application Details
-
River width: 20m
-
Flowrate: 1000 - 30000 l/s (3600 - 108000 m3/hr)
-
Level range: 1 - 4 metres

Application
Solution
-
An Ultraflux Ultrasonic river flowmeter was specified and installed.
-
Mounting hardware was designed by Flowline. Installation took 2 days
-
The system has been operating for over 17 years with no maintenance.
-
The control unit outputs data to a telemetry system

Solution
Equipment Specified
-
Druck pressure sensor
Applications
-
Rivers
-
Effluent flows
-
Sewers
-
Drains
Key Words
-
Low-velocity
-
Retrofit
-
No maintenance
-
Nature protected site


Installed
bottom of page