top of page
Application: Mining Discharge Water
Solution: Raven-Eye Radar Flowmeter
Application
-
Flows from an old mine into a river needed to be measured
-
Aggressive flow, high solids
-
Flow readings had to be measured and recorded continuously
Application Details
-
Pipe Size: 1000mm
-
Pipe Material: Concrete
-
Flowrate: Part full pipe, 360 m3/hr

Application
Solution
-
The Flow-Tronic Raven-Eye radar flowmeter was specified and installed.
-
The system was web-enabled to allow remote reporting
Equipment Specified
-
with ultrasonic level sensor
-
IFQ DC powered control unit with a built-in data logger to record flows
-
Web-enabled data logger
Applications
-
Sewer flows
-
Leakage and infiltration
-
Industrial effluent
Key Words
-
Non-contact, Radar
-
Contaminated flow
-
Industrial effluent
-
Retrofit

Solution

bottom of page