top of page

Application: Mining Discharge Water

Solution: Raven-Eye Radar Flowmeter

Application

  • Flows from an old mine into a river needed to be measured

  • Aggressive flow, high solids

  • Flow readings had to be measured and recorded continuously

Application Details

  • Pipe Size:  1000mm

  • Pipe Material: Concrete

  • Flowrate:   Part full pipe, 360 m3/hr

Radar flowmeter Mine Discharge

Application

Solution

Equipment Specified 

Applications

  • Sewer flows

  • Leakage and infiltration 

  • Industrial effluent

Key Words

  • Non-contact, Radar

  • Contaminated flow 

  • Industrial effluent

  • Retrofit