top of page

Application: Sewage works aeration pipes

Solution: Thermal Mass Flowmeter

Application

A large sewage treatment works needed to measure air flows in aeration feed pipe.

Flows could not be shut down but the pipes could be "hot tapped" to allow a small valve to be fitted.

​

Application Details

  • Pipe Size:  600mm

  • Pipe Material: Steel

  • Flowrate:   25000 m3/hr

  • Temperature: 100 DegC

Solution

Equipment Specified 

Applications

  • Compressed Air

  • Gas distribution

  • Sample air

Key Words

  • Insertion meter

  • Retrofit

  • No shutdown

Thermal mass flowmeter
Thermal mass Flowmeter for air and gas

Application

Hoentzsch thermal mass flow meter

Solution

Thermal mass flowmeter installed in air pipe

Installation

bottom of page